Fire Safety Signs

Firefighters and residents rely on these signs when something goes wrong. The FDNY fire safety notice goes inside every apartment door and near the mailboxes (3 RCNY Section 401-06). Standpipe signs mark hose connections, the In Case of Fire Use No Water sign goes on every door of a room where water would be hazardous (Building Code Section 905.1), and the main line disconnect switch sign marks the service disconnect.The elevator main line location sign is good practice, not a code requirement. Check your Certificate of Occupancy before ordering fire safety notices, because it tells you whether you need the fireproof or non-fireproof version.

Who needs these signs

Apartment buildings with 3 or more units, under the Fire Code and FDNY’s rules. The fire safety notice applies to every one of them, in two versions: one for fireproof (non combustible) buildings that tells residents to stay in their apartment unless the fire is inside it, and one for non fireproof (combustible) buildings that tells them to leave if they safely can. Standpipe, sprinkler and elevator signs apply where the building has that equipment.

The law behind each one

The fire safety notice is Fire Code Section 401.6 and 3 RCNY 401-06: 5.5 by 8.5 inches, at least 10 point, on laminated paper, paper under plexiglass or 3 mil matte vinyl, one inside every apartment entrance door and one in the lobby near the mailboxes at 4 to 5.5 feet, with the Building Information Section posted beside the lobby copy. The Close the Door sign is Admin Code Section 15-135 (Local Law 115 of 2018) on the hallway side of every stair door. The elevator landing sign is Building Code Section 3002.3 on every floor of an elevator building. Standpipe and sprinkler connection signs follow the Fire Code’s marking rules for the connections firefighters use.

Where they go

Fire safety notices on the inside of each apartment door and in the lobby. Close the Door signs at eye level on the corridor side of each stair door. The elevator sign above the call button with its top no more than 6 feet up. Standpipe signs at the siamese connection and at each hose valve, where they can be read with a flashlight.

Read which fire safety notice your building needs, the apartment door notice guide and the Close the Door sign rules before you order.

Quick answers

How do I know if my building is fireproof? Check the certificate of occupancy or DOB’s BIS profile. Type I and II construction is non combustible (fireproof); Type III, IV and V is combustible. Pre war walk ups with wood joists are usually combustible even with brick walls.

How many fire safety notices do I need? One for the lobby and one for the inside of every apartment entrance door. A 12 unit building needs 13, and a Building Information Section sheet goes next to the lobby copy.

How many Close the Door signs do I need? One for every door into a stair enclosure on every floor, including the cellar and roof bulkhead. Count the doors, then add two spares for the ones that get painted over.

Showing all 7 results